EMSのデフォルト設定として、重要な警告やイベントは/var/adm/syslog/syslog.logに、全てのイベントは/var/opt/resmon/log/event.logに記録されます。下記はevent.logのサンプルになります。
>------------ Event Monitoring Service Event Notification ------------<
Notification Time: Tue Dec 4 00:06:40 2007
Hitachi310 sent Event Monitor notification information:
/system/events/ia64_corehw/core_hw is >= 3.
Its current value is CRITICAL(5).
User Comments:
Error
Event data from monitor:
Event Time..........: Tue Dec 4 00:06:40 2007
Severity............: CRITICAL
Monitor.............: ia64_corehw
Event #.............: 103001
System..............: Hitachi310
Summary:
Power Supply : Failure is detected.
Description of Error:
The system has detected that one of the power supplies has failed.
Probable Cause / Recommended Action:
The power supply has failed. Contact your HP support representative to
check the power supply.
For information on the sensor that generated this event, refer to FRU ID
in Event Details section.
Additional Event Data:
System IP Address...: 150.1.1.231
Event Id............: 0x4754fc8000000003
Monitor Version.....: B.01.00
Event Class.........: System
Client Configuration File...........:
/var/stm/config/tools/monitor/default_ia64_corehw.clcfg
Client Configuration File Version...: A.01.00
Qualification criteria met.
Number of events..: 1
Associated OS error log entry id(s):
None
Additional System Data:
System Model Number.............: ia64 hp server rx2620
EMS Version.....................: A.04.20
STM Version.....................: C.56.00
System Serial Number............: **********
Latest information on this event:
http://docs.hp.com/hpux/content/hardware/ems/ia64_corehw.htm#103001
v-v-v-v-v-v-v-v-v-v-v-v-v D E T A I L S v-v-v-v-v-v-v-v-v-v-v-v-v