EMSのデフォルト設定として、重要な警告やイベントは/var/adm/syslog/syslog.logに、全てのイベントは/var/opt/resmon/log/event.logに記録されます。下記はevent.logのサンプルになります。

>------------ Event Monitoring Service Event Notification ------------<

Notification Time: Tue Dec  4 00:06:40 2007

Hitachi310 sent Event Monitor notification information:

/system/events/ia64_corehw/core_hw is >= 3.
Its current value is CRITICAL(5).

User Comments:

Error

Event data from monitor:

Event Time..........: Tue Dec  4 00:06:40 2007
Severity............: CRITICAL
Monitor.............: ia64_corehw
Event #.............: 103001              
System..............: Hitachi310

Summary:
     Power Supply : Failure is detected.


Description of Error:

     The system has detected that one of the power supplies has failed.

Probable Cause / Recommended Action:

     The power supply has failed. Contact your HP support representative to
     check the power supply.

     For information on the sensor that generated this event, refer to FRU ID
     in Event Details section.

Additional Event Data: 
     System IP Address...: 150.1.1.231
     Event Id............: 0x4754fc8000000003
     Monitor Version.....: B.01.00
     Event Class.........: System
     Client Configuration File...........:
     /var/stm/config/tools/monitor/default_ia64_corehw.clcfg 
     Client Configuration File Version...: A.01.00 
          Qualification criteria met.
               Number of events..: 1 
     Associated OS error log entry id(s): 
          None
     Additional System Data:
          System Model Number.............: ia64 hp server rx2620 
          EMS Version.....................: A.04.20 
          STM Version.....................: C.56.00 
          System Serial Number............: ********** 
     Latest information on this event:
          http://docs.hp.com/hpux/content/hardware/ems/ia64_corehw.htm#103001

v-v-v-v-v-v-v-v-v-v-v-v-v    D  E  T  A  I  L  S    v-v-v-v-v-v-v-v-v-v-v-v-v