Supply Record
Customers Year Q'ty Output/
(kW)
Voltage
(V)
Speed
(rpm)
Type
-Form
Type of enclosure Driven Machine
Gencor 1988 3 1,500/
6,600
750 EFZU
-DQ
ODP Mill
Gencor 1987 3 1,025/
6,600
600 TFOA
-KK
TEAAC Fan
Gencor 1987 2 1,500/
6,600
750 EFZOU
-DQ
ODP Mill
Gencor 1987 1 2,000/
6,600
1,500 EFZU
-KK
ODP Pump
Lo Raine Gold Mines 1987 1 1,000/
6,600
1,500 EFOS
-KK
WP-I Compressor
FSCM 1987 1 1,680/
6,600
750 EFU
-MCYI
ODP Mill
Anglo American Corp. 1986 1 4,000/
6,600
750 EFA
-CYI
WP-II Mill
Gold Fields 1986 1 4,200/
6,600
1,500 EFZLUN
-MCYI
ODP Compressor
Anglo American Corp. 1986 6 1,000/
6,600
1,500 TFO
-KK
TEAAC Compressor
BAK 1986 1 261/
550
1,000 TFO
-DYI
TEFC Kane Knife
BAK 1986 1 336/
550
1,000 TFO
-DYI
TEFC Kane Knife
Anglo American Corp. 1986 1 4,800/
6,600
1,500 TFLW
-KK
TEWAC Compressor
J.C.I. 1986 2 4,800/
6,300
1,500 EFLU
-KK
ODP Compressor
Gencor 1986 3 1,000/
6,600
3,000 EFZLU
-KK
ODP Compressor
Gold Fields 1985 3 1,300/
6,600
1,500 TFOA
-KK
TEAAC Pump
AIRCO 1985 4 835/
6,600
3,000 TFOA
-KK
TEAAC Compressor
Anglovaal 1985 3 1,000/
6,600
1,500 EFOS
-KK
WP-I Compressor
Anglo American Corp. 1985 1 630/
6,600
3,000 TFA
-KK
TEFC Pump
Anglovaal 1985 1 300/
2,100
300 SO
-DQ
ODP Winder
Gencor 1985 2 1,200/
6,600
3,000 EFU
-KK
ODP Compressor
Gold Fields 1985 12 1,575/
6,600
1,500 TFW
-KK
TEAAC Pump
J.C.I / Gold Mine 1985 1 3,000/
6,600
1,500 EFLU
-KK
ODP Pump
Gencor 1985 6 1,000/
6,600
3,000 EFZLU
-KK
ODP Compressor
Anglovaal 1985 1 400/
3,300
750 TFOA
-DY
TEFC Mill
Anglovaal 1985 1 4,000/
6,600
1,500 EFLU
-KK
ODP Compressor
Gencor 1985 1 410/
6,600
1,000 EFOU
-KK
ODP Fan
Anglo American Corp. 1985 1 802/
6,600
3,000 EFOU
-KK
ODP Compressor
Gencor 1985 1 1,500/
6,600
1,500 EFU
-KK
ODP Pump
Gencor 1985 1 500/
6,600
1,500 EFOU
-KK
ODP Pump
Gencor 1985 2 1,500/
6,600
750 EFZOU
-DQ
ODP Fan
Loraine G.M. 1984 2 1,120/
6,600
500 EFBU
-DQ
ODP Winder
Anglo American Corp. 1984 1 2,250/
6,600
750 EFU
-KK
ODP Fan
Anglo American Corp. 1984 3 2,100/
6,600
750 TFA
-KK
TEAAC Fan
J.C.I. 1984 2 1,425/
6,600
500 EFBU
-DQ
ODP Winder
Anglo American Corp. 1984 4 1,250/
6,600
3,000 TFA
-KK
TEAAC Pump
Anglo American Corp. 1984 5 1,500/
6,600
3,000 TFA
-KK
TEAAC Pump
Gold Fields 1984 6 3,600/
6,600
1,500 TFL0W
-KK
TEWAC Pump
Anglo American Corp. 1984 1 985/
6,600
1,500 TFA
-KK
TEAAC Pump
Gold Fields 1984 4 1,570/
6,600
1,500 TFW
-KK
TEAAC Pump
Sulzer 1984 1 4,600/
6,600
1,500 EFZLUN
-MCYI
ODP Compressor
J.C.I. 1984 2 2,280/
6,600
750 EFA
-MCYI
WP-II Mill
Anglo-Transvaal 1984 2 300/
2,200
3,000 EFOA
-KK
TEFC Pump
Gencor 1984 10 250/
6,600
3,000 EFOS
-KK
WP-I Pump
Gencor 1984 4 350/
6,600
3,000 EFOS
-KK
WP-I Pump
Gencor 1984 5 250/
6,600
1,500 EFOS
-KK
WP-I Pump
Anglo American Corp. 1984 1 630/
6,600
3,000 TFA
-KK
TEFC Blower
Gencor 1984 1 410/
6,600
1,000 EFOU
-KK
ODP Fan
Gold Fields 1984 2 784/
6,600
3,000 EFOU
-KK
ODP Compressor
Gencor 1984 1 375/
6,600
1,000 EFOU
-KK
ODP Fan
J.C.I. 1984 2 1,250/
6,600
750 EFOA
-MCYI
WP-II Mill

Page 1 of 9 pages