Installation diagram : Inclined Type [ EN115 Basis ]
Type S1000MXIB
(Unit: mm)
Type
S1000MXIB
W3
1590
W2
1550
W1
1004
W
1210
Table of Bearing Reaction Force (The unit of L
1
~L
4
in the equation is in millimeter)
Type ⁄ Support
R1(N)
R2(N)
R3(N)
R4(N)
R5(N)
S1000MXIB
Motor capacity
7.5kW
or Less
5.5L
1
+20000
5.4(L
1
+L
2
)
5.2(L
2
+L
3
)
5.2(L
3
+L
4
)
5.2L
4
+10000
11kW
5.5L
1
+25000
5.4(L
1
+L
2
)+3000
Close