Work to be Done by Building Contractors

Construction-Related Work

No. Work Description
1 Opening of holes in floor slabs for installation use and recovery work
2 Installation of supporting beams for installation use
3 Opening of suspension holes in floor slabs or sleeve holes for carrying the escalator into place and recovery work
4 Lowest floor and escalator bottom pits and waterproofing work (If there is any resident room below the lower machinery room, the pit work will be of refractory construction)
5 Finish work for floors and ceilings around the escalator after completion of installation
6 Work for handrails and walls around the escalator
7 External of escalator
8 Installation of guard plates in the triangle in places where the escalator and a double ceiling or one escalator and another intersect
9 If the space between escalators is a stairwell, installation of intermediate down walls, ceilings, handrails, and advance prevention partitions
10 Joint work in places where the escalator and building's ceiling border
11 Installation of fall protection nets, etc. if the escalator and the building's floor is a stairwell or the space between one escalator and another is a stairwell
12 Preparation of an entrance to carry in the escalator and recovery work if the escalator is to be installed in the existing building.
13 Protection work around the escalator if the escalator is to be installed in the existing building
14 Opening of a hole in the wall if the operation panel of the escalator is to be installed in the building's wall

Electrical Equipment-Related Work

No. Work Description
15 Power supply for the drive motor: lead-in up to the upper control board of the escalator
16 Power supply for inspection (including bottom lighting): lead-in up to the upper control board of the escalator
17 Grounding wire: lead-in up to the upper power receiving panel of the escalator
18 Piping and wiring for the supervisory panel: lead-in from the installation area of the supervisory panel to the power receiving panel of the escalator
19 Piping and wiring work if the escalator's operation panel is separately installed (built into the wall, etc)
20 Selector switch and its installation for escalator bottom lighting
21 Installation of emergency lighting
22 Installation of sprinklers, broadcasting speakers, guide lights, etc.